Instalacja antenowa na dachu 3 i 6c rotor RAK zasilanie i inne pytania
    9A3AQ pisze:

    Hi Tom!
    Here description solution in my case. I have distance between shack and antena abt 30m. Near antenna mast I instal PS 230/13V- abt 15A and connect 6 and 3cm with DC.For 230V AC 3x0,75mm2 30m long; for DC 2x4mm2 2x 2m long.
    Rotation ( asimuth KR400 and elevation Actuator ) abt 30m multi lead cable (original for phone instalation) with wire 0,25mm2. For elevation indication one mechanical connected potentiometer( abt 1k ) is used. Lines for indication have only one wire 0,25mm2, but in lines for motor( in KR400 and actuator ) is 2 wire in paralel conected.
    For IF RF is RG213 used.. for output RF is used FSJI50 1/4" coax.
    Isolation problem - influence 6cm TX in 3cm RX ( and ereverse) is solved, that in same time BOTH transverter is on TX... or BOTX on RX !!!
    GL+73 !
    Zlatko



Hello Zlatko
Thank you very much for a detailed description of your trv power supply and rotor. Very informative information. In particular information about separation between receivers. Can you write more about the simultaneous operation of the rx and tx lines in both trx?

73's Tom sq4fks


  PRZEJD NA FORUM